Sector · Semiconductors · 28 Jul 2026 · Brief

Lab notebook: wet-bench bath #7 and the lifetime nobody logged

Bath age, spike chemistry, and changeout triggers decide particle and etch drift—semiconductor wet-process notebook, not UPW loop purity, not CDA dew point, not photoresist track logistics.

Notebook: Wet Process · Bench 3 · Bath #7 (SC-1 sibling chemistry, anonymized)
Rule of this book: ink only; no “we’ll update MES later”


2026-07-12 — Install / fill

New bath mixed to target. TOC and particles baseline recorded. Operator: J.K.
Note: heater PID tuned; recirculation filter DP = 0.4 bar.


2026-07-18 — “Still fine”

Visual OK. No titration. Production asked to defer changeout “until weekend.”
Margin note (supervisor): weekend is not a chemical property.


2026-07-21 — First whisper

Metrology: slight particle uptick on wafers exiting this bench only. Split lot confirms bench-correlated.
Action taken: none. Action discussed: “monitor.”


2026-07-23 — Titration (finally)

Active species low vs target. Stabilizer odd. Filter DP 1.1 bar.
Bath age: 11 days against a soft SOP max of 7 “or by titration.”

Wet bench bath tank with recirculation filter and sample port

If titration is optional, lifetime is folklore.


2026-07-23 — Changeout

Drain / rinse / refill. Filter replaced. Baseline restored within two lots.
Scrap already booked to “unknown fab particles” for three days.


2026-07-25 — Rule rewrite in this book (not in a slide)

Changeout triggers (any one fires):

  1. Calendar max hours (hard)
  2. Titration outside window (hard)
  3. Filter DP limit (hard)
  4. Bench-correlated particle signature (hard)
  5. Production preference (never)

Cross-checks pasted from adjacent pages

| Signal | Bath #7 | Bath #6 (control) | | --- | --- | --- | | Particle delta | + | flat | | Titration | late | on schedule | | Filter DP | high | nominal | | Ownership | shared shrug | named wet owner |


Adjacent fences

UPW owns facility water purity. CDA owns dry air. Photoresist track owns coat/develop. AMC hunts own airborne organics. None of them own bath titration cadence on Bench 3. Do not blame UPW for a bath you refused to titrate.

Titration cart beside a wet bench with dated log sheet

The notebook is the control system until MES enforces the same gates.


Last line (2026-07-28)

Bath #7 is a reminder: wet lifetime is measured, not negotiated. If it is not in the book with a time, it did not happen.