Pendant log: payload/inertia lies and the following-error that wasn’t tuning

EOAT mass, inertia tensors, and teach-speed proofs decide whether path accuracy survives takt—robotics pendant event log, not commissioning punch lists, not dress-pack guides, not tool-changer dock seals.

Source: Teach pendant / robot log extract (anonymized cell)
Filter: payload, inertia, following error, speed override
Reader note: this is a log, not a tuning sermon

12:01:14  PAYLOAD SET  m=4.2 kg   (comment: "temp gripper")
12:01:22  INERTIA      default   (unchanged)
12:18:03  SPEED        100% production try
12:18:11  FOL_ERR      Axis J5  (recoverable)
12:18:11  OP           "increase gain?" 
12:19:40  GAIN         +15% (unauthorized)
12:19:55  FOL_ERR      J5 again + J4
12:20:02  E-STOP

Interpretation block (written after the fact)

EOAT was revision B (heavier jaws). Pendant still carried revision A mass. Inertia left at default. Following error was honesty. Gain bump was denial.

Teach pendant showing payload parameters beside a robot EOAT

If mass is wrong, every gain story is fan fiction.


Earlier same shift (missed)

09:14:02  TOOL CHANGE  EOAT-B installed
09:14:10  CHECKLIST    "payload updated?"  → blank
09:14:11  RELEASE      to production queue

Blank checklist boxes are how logs become scrap.


Required log events going forward

| Event | Must write | Block if missing | | --- | --- | --- | | EOAT install | mass + inertia ID | yes | | Path release to takt | teach@100% proof | yes | | Gain change | MoC ID | yes | | Following error | payload dump snapshot | yes |


Contra-log (what we will not do)

  • “Tune it out” before weighing EOAT
  • Copy gains from a sister cell with different tooling
  • Treat pendant comments as CMMS

EOAT on a scale during mass verification

Scales are cheaper than servo funerals.


Adjacent fences

Commissioning punch lists own open safety items. Dress-pack / grease guides own cable and seal environment. Tool-changer briefs own dock air. Muting protocols own scanner proofs. None of them own payload/inertia truth in the motion model. Do not raise gains to hide a heavier jaw.


Final log line

13:02:44  PAYLOAD SET  m=6.1 kg  inertia=EOAT-B
13:03:10  SPEED        100%  FOL_ERR clear
13:03:11  NOTE         "gain reverted; physics restored"